Página 1 - User’s Guide

DL3800EInverse MultiplexerUser’s GuidePart 098-30380-01 Rev FJuly 9, 2001

Página 2 - PRODUCT LIMITED WARRANTY

x DL3800E Inverse Multiplexer User’s Guide — July 9, 2001Front Panel LEDs 5-3Access Levels And Protected Mode 5-4Power Up And Reset 5-5Top Menu 5-5Sel

Página 3 - DISCLAIMER

5-12 DL3800E Inverse Multiplexer User’s Guide — July 9, 20015TEST MENUThe TEST MENU is used to activate network loopbacks and DTE loopbacks. The TEST

Página 4 - YEAR 2000 COMPLIANCE

Front Panel Interface 5-135NOTE: A menu item will appear only for those E1 network interfaces. installed.DTE TESTSNET 2 TESTSNET 3 TESTSNET 4 TESTSENT

Página 5 - INTERNATIONAL COMPLIANCE

5-14 DL3800E Inverse Multiplexer User’s Guide — July 9, 20015DTE TESTSOnly one loopback can be initiated through the DTE TESTS MENU, a bi-directional

Página 6 - COMPLIANCE

Front Panel Interface 5-155Network Tests (1-8)Three NETWORK TESTS can be performed through this menu: PAYLOAD (PAYLD) LOOPBACK, LINE LOOPBACK and LOCA

Página 7 - Table of Contents

5-16 DL3800E Inverse Multiplexer User’s Guide — July 9, 20015Line LoopbackThe Lineloopback is used to verify the operation of the E1 network connectio

Página 8 - Chapter 3, Installation 3-1

Front Panel Interface 5-175CONFIGURATION MENUThe CONFIGURATION MENU is used to back up the database and to view and change the unit and Comm Port Conf

Página 9

5-18 DL3800E Inverse Multiplexer User’s Guide — July 9, 20015Table 5-4 CONFIGURATION MENU ItemsMenu DefinitionBackup Database Used to manually backup

Página 10 - Chapter 6, Diagnostics 6-1

Front Panel Interface 5-195Node ConfigurationThe NODE CONFIG MENU allows you to configure the NODE ID, NODE NUMBER, DATE & TIME and *NODE COMM POR

Página 11 - Glossary G-1

5-20 DL3800E Inverse Multiplexer User’s Guide — July 9, 20015The NODE CONFIGURATION MENU is used to configure various parameters of the DL3800E, inclu

Página 12 - Index I-1

Front Panel Interface 5-215Table 5-5 NODE CONFIGURATION MENU ItemsParameter DefinitionUnit ID The Unit ID is an alphanumeric designation up to 16 char

Página 13 - List of Figures

xiAppendix A, Specifications A-1E1 Network Interface A-1External Clock Interface A-1DTE Interface A-2COMM PORT A-2NMS Port (SNMP) A-2Front Panel A-3D

Página 14

5-22 DL3800E Inverse Multiplexer User’s Guide — July 9, 20015Local Terminal XON/XOFF With the Flow Control feature On, the terminal can request that t

Página 15 - List of Tables

Front Panel Interface 5-235Note that both the NODE HW (HARDWARE) REV and the NODE SW (SOFTWARE) REV are set at the factory and cannot be changed.PARIT

Página 16

5-24 DL3800E Inverse Multiplexer User’s Guide — July 9, 20015DTE Configuration MenuThis menu allows you to set various configurable items for the DTE

Página 17 - ORGANIZATION

Front Panel Interface 5-255

Página 18 - CONVENTIONS

5-26 DL3800E Inverse Multiplexer User’s Guide — July 9, 20015Network ConfigThe NETWORK CONFIG MENU allows you to change various configurable items com

Página 19 - Typography

Front Panel Interface 5-275

Página 20 - RETURNING A UNIT

5-28 DL3800E Inverse Multiplexer User’s Guide — July 9, 20015NET N ConfigThe NET N CONFIG MENU allows you to change various configurable items common

Página 21 - DOCUMENT CHANGE RECORD

Front Panel Interface 5-295Pressing Enter when NET THRESHOLDS appears in the display screen will start the menu and allow you to scroll, using the dow

Página 22

5-30 DL3800E Inverse Multiplexer User’s Guide — July 9, 20015To turn a Major Alarm ON or OFF, use the UP and DOWN ARROW buttons to get the specific al

Página 23 - Quick Install Guide 1

6-16Diagnostics 6EQUIPMENT RETURN AND REPAIRIf faulty equipment is suspected, perform the tests in this section. If, after performing these tests, the

Página 24 - DTE Configuration

xii DL3800E Inverse Multiplexer User’s Guide — July 9, 2001Index I-1

Página 25 - Save Configuration

6-2 DL3800E Inverse Multiplex User’s Guide — July 9, 20016Figure 6-1 TESTS MENU DTE/Network Loopback Test Use the DTE/NETWORK Loopback test to verify

Página 26

Diagnostics 6-36Payload Loopback and Line Loopback TestsUse the PAYLOAD Loopback and LINE Loopback tests to verify the proper operation of the DL3800E

Página 27 - Introduction 2

6-4 DL3800E Inverse Multiplex User’s Guide — July 9, 20016accomplished through DTE loopback and a self test. Testing for the proper functioning of t

Página 28 - PRODUCT FEATURES

Diagnostics 6-56The NETWORK E1 port LED’s on the DL3800E unit never illuminate.Make sure the E1 cable from your service provider is connected to the D

Página 29 - Application

6-6 DL3800E Inverse Multiplex User’s Guide — July 9, 20016The NETWORK E1 LEDs on an DL3800E unit are flashing green.Make sure a valid DTE device is co

Página 30 - FUNCTIONAL DESCRIPTION

Diagnostics 6-76The connected DTE device shows intermittent errors.Run a DTE/NET Loopback to verify the physical connection between the local DTE devi

Página 31 - E1 Port Crossover Detection

6-8 DL3800E Inverse Multiplex User’s Guide — July 9, 20016You cannot access the DL3800E unit from a terminal.The terminal must be running a VT100 or c

Página 32 - Overhead Functions

A-1ASpecifications AE1 NETWORK INTERFACEEXTERNAL CLOCK INTERFACEParameter SettingInterface Type E1Number of Ports 2, 4, 6 or 8Framing Formats CRC4 (En

Página 33 - Installation 3

A-2 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001ADTE INTERFACECOMM PORT NMS PORT (SNMP)Item InterfaceElectrical Interface HSSI or V.35/RS-4

Página 34 - MOUNTING

Specifications A-3AFRONT PANELDIAGNOSTICSPOWERENVIRONMENTALItem InterfaceDisplay 16 Character AlphanumericKey Pad Four KeysDTE Status LEDs TD, RD, R

Página 35 - POWER CABLES AND CONNECTIONS

xiiiList of FiguresFigure 1-1 DL3800E Inverse Multiplexer (front panel) 1-1Figure 2-1 DL3800E Inverse Multiplexer 2-1Figure 2-2 Typical Application fo

Página 36 - EFS 00.0 PERCENT

A-4 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001APHYSICAL /CONNECTORSEXTERNAL ALARM CONTACTSStorage Temperature -20oC to 60oCRelative Humid

Página 37 - DTE CABLE AND CONNECTION

Specifications A-5AThe External alarms are used to turn on a Bell or Light to indicate that an alarm has occurred on the DL3800E. Either the Major, Mi

Página 38 - Telnet Connection

A-6 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001A

Página 39 - Daisy Chaining

B-1BPinouts BTERMINAL CONNECTIONDCE CONNECTORSTable B-1 COMM and NMS Port Pin AssignmentsSIGNAL DIRECTION PINReceive Data To Terminal 2 RD Send Data

Página 40

B-2 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001BCHANNEL 1 DATA CABLE PIN ASSIGNMENTSThe pin assignments for the V.35, M-34 to DB-25 DTE ca

Página 41 - Terminal Interface 4

Pinouts B-3BTable B-4 EIA-530, DB-25 to DB-25 DCE Connector Pin AssignmentsDB-25 DB-25 SIGNAL17352411SCTE725419RTS246163RD224142TD1118625DSR278135CTS1

Página 42 - TERMINAL OPERATION OVERVIEW

B-4 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001BDB-25 to DC-37 Data Port Cable Pin AssignmentsThe pin assignments for the DB-25 to DC-37 D

Página 43

Pinouts B-5BCOMMUNICATION PORT PIN ASSIGNMENTSRS-449, DC-37 to DB-25 DCE Cable Pin Assignments Table B-6 describes the RS-449, DC-37 to DB-25 DCE cabl

Página 44 - SELECT LOCAL/REMOTE

B-6 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001BE1 NETWORK PIN ASSIGNMENTSThe network connector is a DA-15 connector. The assignments for

Página 45 - ALARMS AND STATUS

Pinouts B-7BX.21 TO DB-25 CABLE PINOUTSEXTERNAL CLOCK CONNECTOR PIN ASSIGNMENTSA DE-9 connector is provided on the DL3800E unit rear panel for connect

Página 46 - ALARM DESCRIPTION

xivFigure 4-12 DTE CONFIGURATION MENU (HSSI) 4-22Figure 4-13 Network Configuration Screen 4-26Figure 4-14 Network Thresholds Configuration 4-29Figure

Página 47

B-8 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001BPer RS-422 requirements, the receiver has an input sensitivity of 200 mV over the input vo

Página 48

Pinouts B-9BALARM PINOUTPin Assignments for the Alarm connector are as follows:Table B-11 Alarm PinoutMaj - MajorMin - MinorNC - Normally Closed (unle

Página 49

B-10 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001BDC POWER CONNECTIONSFigure B-1 DC Power ConnectionsDTE CLOCK RATESTable B-12 DTE Clock Ra

Página 50

C-1CFactory Default Settings CTable C-1 Unit SettingsUnit SettingALARM ENABLE DisabledAUTOMATIC BACKUP 5 minutes after each database changeFRONT PANEL

Página 51 - Statistics

C-2 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001CTable C-3 Network SettingsNetwork SettingALARM MaskACTIVE/RESTORE MODE Never UseFRAME CRC4

Página 52

Factory Default Settings C-3CBITS & PARITY 8 bits, No paritySTOP BITS 2Table C-6 Test SettingsTests SettingALL LOOPBACKS & TESTS OffTable C-5

Página 53

C-4 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001C

Página 54

G-1GGlossary GAABAMA designation for 22-gauge, 110-ohm, plastic-insulated, twisted-pair Western Electric cable normally used in central offices.AIS (A

Página 55 - Event History

G-2 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001GBB8ZS (Bipolar 8 Zero Substitution)A technique used to accommodate the ones density requir

Página 56 - Alarm Parameter Definition

Glossary G-3GbroadbandServices or interfaces that operate above the T1 data rate, typically at NxT1, T3, SONET, or ATM speeds.BPV (Bipolar Violation)O

Página 57 - Configuration

xvList of TablesTable 4-1 Main Menu 4-4 Table 4-2 3800E Alarm Descriptions 4-5 Table 4-3 NET Statistics Items 4-13Table 4-4 Alarm Level 4-16Table

Página 58 - Option Action

G-4 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001GconnectorA physical interface, such as DB-15 or RS-232-C, typically with male or female co

Página 59

Glossary G-5Gdata linkAny serial data communication transmission path, generally between two adjacent nodes or devices and without any intermediate sw

Página 60

G-6 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001GDSU LoopbackA DSU loopback is intended to include as much of the customer data communicati

Página 61

Glossary G-7GequalizationThe spacing and operation of amplifiers so that the gain provided by the amplifier, per transmission frequency, coincides wit

Página 62

G-8 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001Gframe relayA high-speed packet switching protocol used for wide area networks (WANs); fast

Página 63 - Parameter Description/Action

Glossary G-9GLOF (Loss of Frame)Occurs when a received digital signal loses frame synchronization. LOFC (Loss of Frame Count)A count of declared Loss

Página 64

G-10 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001GmultidropA communications arrangement where multiple devices share a common transmission

Página 65

Glossary G-11GpolarityAny condition where there are two opposing charges, such as positive and negative.portThe physical point of access into a comput

Página 66

G-12 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001GRS232-CAn EIA specified physical interface, with associated electrical signaling, between

Página 67

Glossary G-13GSG (Signal Ground)A signal from DTE to DSU/CSU.simplex currentOne way transmission used by Telco to provide power to repeaters. SLIP

Página 68 - Network Thresholds

xvi DL3800E Inverse Multiplexer User’s Guide —July 9, 2001Table B-1 COMM and NMS Port Pin Assignments B-1 Table B-2 HSSI DCE Connector Pin Assignments

Página 69

G-14 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001GT-CarrierA time-division, multiplexed digital transmission facility, usually operating at

Página 70 - System Utilities

I-1IIndex IAAlarm Level 4-16Alarms and Status 4-5Application 2-3Audience xviiAWG tray cable 3-3BButton Overview 5-1Ccableinstalling DC power 3-4cable

Página 71 - Software Download

I-2 DL3800E Inverse Multiplexer User’s Guide — July 9, 2001INNET (1-8) Statistics 5-9NET (1-8) Status 5-9NET N Config 5-28NET STATISTICS MENU Informat

Página 72

xviiPrefaceThe DL3800E Inverse Multiplexer User’s Guide provides the information you need to install, test, operate, and manage the DL3800E Inverse Mu

Página 73 - Software Download Options

xviii DL3800E Inverse Multiplexer User’s Guide — July 9, 2001CONVENTIONSThis section describes the formats used to differentiate specific types of inf

Página 74 - RAM Software Options

Preface xixTypographyQuick Eagle Networks manuals delineate the names of files, commands, and actions by using the fonts and typefaces described in th

Página 75 - Terminal Interface 4-35

COPYRIGHT AND TRADEMARKSCopyright © 2001, Quick Eagle NetworksWorld copyright reserved. No part of this publication may be stored in a retrieval syste

Página 76

xx DL3800E Inverse Multiplexer User’s Guide — July 9, 2001QUICK EAGLE NETWORKS TECHNICAL SUPPORTIf you should experience difficulty with the setup and

Página 77 - Login Configuration

Preface xxiSEND US YOUR COMMENTSPlease let us know if this user guide manual meets your requirements.Does the manual answer your questions?Is the manu

Página 78

xxii DL3800E Inverse Multiplexer User’s Guide — July 9, 2001

Página 79 - SNMP Configuration

1-11Quick Install Guide 1PURPOSEThis chapter is a quick reference for the setup and configuration of the DL3800E Inverse Multiplexer (see Figure 1-1).

Página 80 - Option Description/Action

1-2 DL3800E Inverse Multiplexer User’s Guide — July 9, 20011SetupTerminal Log OnConnect your terminal to the COMM port on the back of the DL3800E unit

Página 81

Quick Install Guide 1-31Network ConfigurationSet up a port for each E1 line you plan to use. Set Alarm to Report. Set ACTICVE/RESTORE MODE to Use w/au

Página 82 - In-Band SNMP to Remote

1-4 DL3800E Inverse Multiplexer User’s Guide — July 9, 20011

Página 83 - Figure 4-20 TESTS MENU

2-12Introduction 2SYSTEM OVERVIEWThe DL3800E Inverse Multiplexer bridges the gap between E1 and E3 data services by providing E1 multiplexing of multi

Página 84 - DTE/Network Loopback

2-2 DL3800E Inverse Multiplexer User’s Guide — July 9, 20012The DL3800E unit features an automatic rate fallback in the event of a failing E1 circuit.

Página 85 - Remote Loopback Detection

Introduction 2-32System BenefitsThe numerous features of the DL3800E unit provide you with many benefits:• Reliable, full performance access to E1 net

Página 86 - Manual Network Restoration

Buyer's exclusive remedy, and Quick Eagle Networks' total liability, for any and all losses and damages arising out of any cause whatsoever

Página 87 -

2-4 DL3800E Inverse Multiplexer User’s Guide — July 9, 20012FUNCTIONAL DESCRIPTIONThe base DL3800E unit configuration consists of a motherboard with t

Página 88

Introduction 2-52When the incoming signal is framed on the inverse mux frame, the framer will start loading its Dual Port RAM. The address to the Dual

Página 89 - Front Panel Interface 5

2-6 DL3800E Inverse Multiplexer User’s Guide — July 9, 20012Figure 2-3 DL3800E Unit Functional SchematicOverhead FunctionsThe overhead functions consi

Página 90 - Enter Button

3-13Installation 3INSTALLATION1. Unpack and inspect the DL3800E unit for damage that might have occurred during shipment. If necessary, wipe off the e

Página 91 - Front Panel LEDs

3-2 DL3800E Inverse Multiplexer User’s Guide — July 9, 200138. Configure Unit See “Unit Configuration” on page 4-17 (ASCII terminal)a. Configure COMM

Página 92

Installation 3-33POWER CABLES AND CONNECTIONSThe DL3800E unit can be ordered with an AC or DC power supply.AC Power ConnectionAn AC power cord is supp

Página 93 - TOP MENU

3-4 DL3800E Inverse Multiplexer User’s Guide — July 9, 200134. Connect the ground (+) wire to the + terminal in the same way.5. Connect the frame grou

Página 94 - CONFIGURATION

Installation 3-53E1 NETWORK CONNECTIONThe eight port connector can be either a DB-9, DB-15, or BNC. The connectors are located on the DL3800E unit bac

Página 95 - DISPLAY MENU

3-6 DL3800E Inverse Multiplexer User’s Guide — July 9, 20013Direct ConnectionFor direct connection, using the appropriate DE-9 cable, connect the ASCI

Página 96

Installation 3-73Daisy Chaining Multiple DL3800E units can be daisy-chained together through the Terminal Port to provide centralized network monitori

Página 97 - NET (1-8) Statistics

RIGHTS TO SOFTWAREQuick Eagle Network ("QEN") software products are proprietary to QEN and shall remain the property of QEN. Other than the

Página 98

3-8 DL3800E Inverse Multiplexer User’s Guide — July 9, 20013

Página 99

4-14Terminal Interface 4LOG IN/LOG OFFEach DL3800E unit is equipped with an integrated RS-232 ASCII user interface that can be accessed through the CO

Página 100 - TEST MENU

4-2 DL3800E Inverse Multiplexer User’s Guide — July 9, 200144. To log on to another DL3800E unit on the same daisy chain, simply type Ctrl-X, followe

Página 101

Terminal Interface 4-34The next two lines in the menu, which are always highlighted, represent the Status Bar. The first line of the Status Bar displa

Página 102 - DTE TESTS

4-4 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014INVERSE MULTIPLEXER MAIN MENU COMMANDSWhen a DL3800E unit is first powered up, the Main Me

Página 103 - Payload Loopback

Terminal Interface 4-54ALARMS AND STATUSThe ALARMS AND STATUS MENU is a view-only screen that allows you to review the current ALARMS AND STATUS items

Página 104 - Local Loopback

4-6 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014AIS DET Alarm Indication Signal Detected — Net Port detects an unframed continuous stream

Página 105 - CONFIGURATION MENU

Terminal Interface 4-74SES Threshold Net Port has exceeded the Severely Errored Second Threshold.UAS Threshold Net Port has exceeded the Unavailable S

Página 106

4-8 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014ROM Checksum Fail This occurs if the checksum for the code image stored in ROM does not ma

Página 107 - Node Configuration

Terminal Interface 4-94DTE Loss The signal indicating DTE presence has been lost.DTR On The V.35 DTR signals is present.RTS On The V.35 RTS signal is

Página 108

Malfunction of the equipment: In the event this equipment should fail to operate properly, disconnect the unit from the telephone line. Try using anot

Página 109

4-10 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014NOTE: Status display will read ACTIVE, if the DL3800E unit is in Inverse Mux mode and re

Página 110 - Parameter Definition

Terminal Interface 4-114StatisticsThis menu allows you to access the performance STATISTICS SUBMENU of any E1 port. Highlight STATISTICS in the INVERS

Página 111 - To node configuration menu

4-12 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014To view the performance statistics of any one E1 port, highlight that port and press Ente

Página 112 - DTE Configuration Menu

Terminal Interface 4-134Figure 4-5 Additional NET STATISTICS.Table 4-3 NET Statistics Items Parameter DefinitionEFS Error Free Seconds (EFS) is calcul

Página 113 - Front Panel Interface 5-25

4-14 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014BPV This display provides the number of Bipolar Violations (BPVs) that have occurred duri

Página 114 - Network Config

Terminal Interface 4-154Event HistoryUse this screen to review and clear the DL3800E unit alarm and status history. To view the EVENT HISTORY, move th

Página 115 - Front Panel Interface 5-27

4-16 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014To clear the report of all History Events, move the highlight bar to CLEAR HISTORY and pr

Página 116 - NETWORK THRESHOLDS

Terminal Interface 4-174ConfigurationThe CONFIGURATION MENU item provides access to a series of submenus to configure various parameters of the unit,

Página 117 - OPTION VALUE

4-18 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014Figure 4-8 UNIT CONFIGURATION MENU Table 4-5 Node Configuration OptionsOption ActionDate

Página 118

Terminal Interface 4-194Front Panel This feature enables (On) or disables (Off) your ability to make changes in the configuration or run tests from th

Página 119 - Diagnostics 6

VCCIREGULATORY COMPLIANCE• European harmonized standards 73/23/EEC/, 91/31/EEC, 89/336/EEC, 93/68/EEC, and 91/263/EEC• UL 1950 3rd Edition• CAN/CSA C2

Página 120 - LOCAL Loopback Test

4-20 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014To update the node database with all the changes made, move the highlight bar to CONFIRM

Página 121 - TROUBLESHOOTING THE DL3800E

Terminal Interface 4-214Figure 4-9 DTE CONFIGURATION MENU (V.35)Figure 4-10 DTE CONFIGURATION MENU (RS449)DIGITAL LINK DL3800E SR 3.00.22 NODE 1:

Página 122

4-22 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014Figure 4-11 DTE CONFIGURATION MENU (X.21) Figure 4-12 DTE CONFIGURATION MENU (HSSI)DIGITA

Página 123 - Problem Solution

Terminal Interface 4-234Table 4-6 DTE CONFIGURATION MENU Options Parameter Description/ActionDTE Interface This allows you to select V.35, RS449, X.21

Página 124

4-24 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014DSR (Data Set Ready) This allows you to Assert, DeAssert, or set to automatic the DSR lea

Página 125

Terminal Interface 4-254Network ConfigurationThis submenu allows you to configure various Network parameters. The configurable parameters include CRC4

Página 126

4-26 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014Figure 4-13 Network Configuration Screen Table 4-7 NETWORK CONFIGURATION MENU Options Par

Página 127 - Specifications A

Terminal Interface 4-274TSLOT16 Allows you to select between DATA and FLAG. If DATA is selected, timeslot 16 will be used for payload data. If FLAG is

Página 128 - DTE INTERFACE

4-28 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014Network ThresholdsThis menu allows you to enable/disable the automatic FALLBACK feature a

Página 129 - ENVIRONMENTAL

Terminal Interface 4-294Figure 4-14 Network Thresholds ConfigurationThrough the CONSECUTIVE THRESHOLDS section of this menu, you disable or enable the

Página 130 - EXTERNAL ALARM CONTACTS

viiTable of ContentsPreface xviiAudience xviiOrganization xviiConventions xviiiSymbols xviiiTypography xixQuick Eagle Networks Technical Support xxRet

Página 131 - Specifications A-5

4-30 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014Save ConfigurationThis option allows you to manually back up the database to EEPROM at an

Página 132

Terminal Interface 4-314Software DownloadThis selection is used to choose the desired mode for upgrading the DL3800E unit software revision level via

Página 133 - Pinouts B

4-32 DL3800E Inverse Multiplexer User’s Guide — July 9, 200141. Copy the files off the floppy onto the hard drive on the PC. The names of the files wi

Página 134

Terminal Interface 4-334Software Download OptionsImmediate Software Activation (Enable/Disable)The IMMEDIATE SOFTWARE ACTIVATION mode is controlled fr

Página 135 - DB-25 DB-25 SIGNAL

4-34 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014RAM Software Options RAM Software Options - Query RAM SoftwareThis feature determines whe

Página 136 - Table B-5

Terminal Interface 4-354TFTP Software DownloadIf immediate software activation is enabled on the target unit, the software is downloaded to the target

Página 137 - DC-37 DB-25

4-36 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014To delete the entire unit configuration, select DELETE ENTIRE UNIT CONFIGURATION from the

Página 138 - DB-25 TO DE-9 ADAPTER PINOUTS

Terminal Interface 4-374To Restart Node Software, select DELETE ENTIRE UNIT CONFIGURATION from the SOFTWARE UTILITIES MENU (Figure 4-17) and press Ent

Página 139 - X.21 TO DB-25 CABLE PINOUTS

4-38 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014Users must have Full Access class to view or change this screen. The name and password ca

Página 140

Terminal Interface 4-394SNMP Configuration Through the SNMP CONFIGURATION MENU, you configure the Network Manager (NMS) port on the rear panel of the

Página 141 - ALARM PINOUT

viii DL3800E Inverse Multiplexer User’s Guide — July 9, 2001Application 2-3Functional Description 2-4Signal Flow 2-4E1 Port Crossover Detection 2-5Ove

Página 142 - DTE CLOCK RATES

4-40 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014Table 4-9 SNMP Configuration OptionsOption Description/ActionUnit IP Address The Unit IP

Página 143 - Factory Default Settings C

Terminal Interface 4-414To update the SNMP database with all the changes made, move the highlight bar to CONFIRM, and press the Enter key. Changes can

Página 144 - SNMP Configuration Setting

4-42 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014However, it is important to note that the remote IMUX’s “Unit IP Address” parameter must

Página 145 - Tests Setting

Terminal Interface 4-434TestsThe TESTS MENU allows you to initiate or stop four types of loopbacks for each individual network port: DTE/NETWORK LOOPB

Página 146

4-44 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014To initiate a test, use the CURSOR keys to move the highlight bar to DTE/Network Loopback

Página 147 - Glossary G

Terminal Interface 4-454Figure 4-21 Loopbacks within the DL3800E unit Remote Loopback DetectionThe DL3800E has the capability of detecting loopbacks w

Página 148

4-46 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014.Manual Network RestorationThe DL3800E’s E1 ports are normally set to auto restore. Howev

Página 149 - Glossary G-3

Terminal Interface 4-474Figure 4-22 MANUAL NETWORK RESTORATION MENUTo manually restore an E1 port (network), use the UP and DOWN ARROW keys to highlig

Página 150

4-48 DL3800E Inverse Multiplexer User’s Guide — July 9, 20014

Página 151 - Glossary G-5

5-15Front Panel Interface 5GENERALThe front panel (Figure 5-1) features a 16 character vacuum fluorescent display and four buttons that help you to mo

Página 152

ixConfiguration 4-17Unit Configuration 4-17DTE Configuration 4-20Network Configuration 4-25Network Thresholds 4-28Save Configuration 4-30System Utilit

Página 153 - Glossary G-7

5-2 DL3800E Inverse Multiplexer User’s Guide — July 9, 20015The front panel buttons are also used for Alarm Cutout. When an alarm condition occurs, th

Página 154

Front Panel Interface 5-35Front Panel LEDsTable 5-1 Front Panel LEDsIndication DescriptionTest Test In Progress LEDOff No tests are in progress.Solid

Página 155 - Glossary G-9

5-4 DL3800E Inverse Multiplexer User’s Guide — July 9, 20015Access Levels And Protected ModeFront panel access can be limited by placing the DL3800E u

Página 156

Front Panel Interface 5-55This procedure takes the unit out of the Protected Mode (and clears any password that may have been programmed) and sets all

Página 157 - Glossary G-11

5-6 DL3800E Inverse Multiplexer User’s Guide — July 9, 20015This menu loop may also be entered at any time by pressing the Exit button to go up the me

Página 158

Front Panel Interface 5-75The Configuration MENU is used to view and change the unit's configuration parameters, date and time, network interface

Página 159 - Glossary G-13

5-8 DL3800E Inverse Multiplexer User’s Guide — July 9, 20015Node (Common Equipment) StatusThis display shows the status of the unit. NODE STATUS is ac

Página 160

Front Panel Interface 5-95DTE StatusThe next display shows the status of the DTE data port. The menu is accessed by pressing Enter when DTE STATUS app

Página 161

5-10 DL3800E Inverse Multiplexer User’s Guide — July 9, 20015Pressing the DOWN ARROW from any of these displays will step you through the last 96 15-m

Página 162

Front Panel Interface 5-115EB/CV An Errored Block (EB) is a block in which one or more bits are in error. The EB if therefore equivalent to the Code V